It s much easier to reseal the flashing than it is to patch a water stained wall or ceiling.

Proper roof flashing techniques.

Apply an approximately 3 inch width of asphalt roofing cement along the sides of flashing and embed shingles in mastic. Install an underlayment centered in the roof valley. Use increased lap lengths for added protection. Lap successive sheets of metal flashing a minimum of 12 inches and seal laps.

That lip is then set into a reglet or groove in this case cut into the mortar joint of the brick wall above. Use fasteners that are compatible with or of the same type of metal as the flashing material. Run the base flashing 4 to 5 in. Recaulk the joints between the roof and the flashing.

Proper roof installation is achieved through experience and sound construction techniques thorough. 1 square foot per 150 square feet of attic floor. Beyond the dormer and cut the top section along the dormer edge. Proper roof wall flashing example to install the roof wall flashing above the builder bent the top edge of the flashing into a 90 degree lip about 2 cm in width.

Edge flashing and starter strip roofs peel off from the edges so it is critical to hold them tight with the roof deck sealed on the outside we turn to flashing the edges with metal and membranes metal drip edge flashing details roofing wrb flashing two ways to flash roof edges. There are two good ways to handle corner flashing. Then install a non corrosive metal valley flashing of 24 minimum width. Do not rely on sealant as a substitute for proper lapping.

Flashing seals areas of transition or penetration where architectural features exterior electrical features plumbing or the roof and walls meet. Vertical flashings must be a minimum of 8 inches above the completed roof surface. Fasten loose nails and cover exposed nail heads with roofing cement. Half the vents should be at the eaves and half at the ridge.

Storm proof roof 2. The edge of the roof has thin metal flashing that helps water drip off. Roof and deck flashing recommendations for coastal areas always lap flashing and other moisture barriers properly. Begins with the proper selection of the roof system for that particular environment there are other important factors to consider such as the roof covering deck ends underlayment flashing and other components.

The 8 inch height prevents water from pouring over the top of the flashings into the building or system. This height has become the industry standard and is recognized by most membrane manufacturers. Open valleys have metal flashing to protect this critical area of the roof. Renew flashing seals by chipping out old caulking and mortar along the edges of the flashing.

Bend the flap down and nail along the top edge.

Pin On Construction Design

Pin On Construction Design

Pin On Home Building Repair Or Rebuild

Pin On Home Building Repair Or Rebuild

How To Roof A House Diy Roofing Roofing Home Construction

How To Roof A House Diy Roofing Roofing Home Construction

Pin Em Roofing

Pin Em Roofing

Source : pinterest.com